Error & LCD Window Message Codes:
ACC (Applied Computer Controls)
CoLd = Temperature in the spa heater housing is below 40° F. Status of the heater element is unknown. The low speed pump or circ pump will operate continuously until the temperature rises above 45° F. OH = Over heat. The spa is at a temperature above 108° . Do not use spa when temperature is flashing or the OH message is displayed. HLoH = Hi Limit Over Heat. Hi limit sensor is disconnected or shorted or the spa temperature is above 112° F. SEoP = Sensor open or disconnected. Heater disabled but the spa is operational. SESH = Sensor short, nonfunctional. Heater disabled but the spa is operational. PSoC = Pressure switch open with circulating pump. PSoL = Pressure switch open with low pump. PSoH = Pressure switch open with high pump. ToE = Time out error. Rare system error. Spa unusable. Contact ACC.
Balboa
pd = Power supply, unit running on battery backup OH = Sensors reading 112-118° F. OHH = Overheat. Spa has shut down. One sensor has detected 118º Fat heater. OHS = Overheat. Spa has shut down. One sensor has detected 110ºF. Flo = Improper flow or pressure switch malfunction Cool = Water temp 20° below set point ICE = Potential freeze condition has been detected Sn1 = Hi-limit sensor malfunction Sn3 = Temp sensor malfunction SnA = Spa is shut down. Sensor plugged into jack A is not working. Snb = Spa is shut down. Sensor plugged into jack B is not working. SnS = Sensors out of balance. If alternating with temp, may be temporary condition. If display shows only this message (blinking) spa is shut down. HFL = Substantial difference between temperature sensors detected. Could indicate a flow problem. LF = Persistent low flow problems. (Displays on the 5th occurrence of "HFL" message with 24 hours). Heater is shut down, but other spa functions run normally. dr = Inadequate water detected in heater. dry = Inadequate water detected in heater. (Displays on third occurrence of "dr" message). Spa is shut down. Pr = When spa is first actuated, it will go into Priming Mode. ILOC = Interlock failure - possible pump or ozone spike . (---) =Unknown water temperature. (Displays when first powered up after refill). Std = Spa operating in Standard Mode. Ecn = Spa operating in Economy Mode. SE = Spa operating in Standard-in-Economy Mode.
Brett Aqualine
OH = Temp exceeds 118° F Fr = Freeze condition - temp below 40° F FL = Pressure switch failure EO = Shorted temp sensor E1 = Open temp sensor E2 = Shorted hi-limit sensor E3 = Open hi-limit sensor E4 = Shorted flow switch E7 = Improper electrical connection
CTI
th1/39 = On startup indicates temperature probe problem. th2/current temperature = On startup indicates temperature probe problem. th3/39 = On startup indicates water temperature less than 39° F. OH = Overheating, water over 112° F. System will restart when temp. drops. hot = Overheating, water over 112° F. System will restart when temp. drops. HL = High limit switch tripped.
Dream Maker Hot Tubs
OH = Overheat 108° F, spa is deactivated. Do not enter the water. FL = Flow. Pressure switch is not working. SN = Non functional high temperature sensor. Heater is deactivated. F2 = 4 hours daily filtration F4 = 8 hours daily filtration F6 = 12 hours daily filtration FC = continuous filtration
EasyPak
C = Celsius CL = Current Time of Day ECdu = Economy Mode Duration Econ = Economy Mode Turn On F = Fahrenheit Fldu = Filter Cycle Duration Flon = Filter Cycle Turn On FLC = Pressure Switch Alarm FLO = Pressure Switch Alarm FrEE = Freeze Protection Alarm HL = High Temperature Alarm Loc = Panel / Keypad Locked PrH = Temperature Sensors Alarm Prr = Temperature Sensors Alarm Tu = Temperature Set Celsius Tu = Temperature Set Fahrenheit
Gecko
FLO = Pressure switch failure, switch open FLC = Pressure switch failure, switch closed Prr = Temp sensor failure Prh = Hi-limit sensor failure HL = Sensor measuring 119° F FrE = Possible freeze condition detected
Hercules
OH = Spa temp exceeds acceptable limits FLO = Flow problem ICE = Freeze condition detected SN1 = Hi-limit sensor failure SN2 = Temp sensor failure
Hurricane
PS = Flow or pressure switch failure SH = Shorted sensor OP = Open Sensor LO = Temp below 60° F - freeze HL = Temp above 118° F
Hydro-Quip
C = Celsius CL = Current Time of Day ECdu = Economy Mode Duration Econ = Economy Mode Turn On F = Fahrenheit Fldu = Filter Cycle Duration Flon = Filter Cycle Turn On FLC = Pressure Switch Alarm FLO = Pressure Switch Alarm FrEE = Freeze Protection Alarm HL = High Temperature Alarm Loc = Panel / Keypad Locked PrH = Temperature Sensors Alarm Prr = Temperature Sensors Alarm Tu = Temperature Set Celsius Tu = Temperature Set Fahrenheit
Jacuzzi Whirlpool
OH = Overheat Protection (Heater is deactivated, pumps low speed is activated). COOL = Spa water is more than 20° F cooler than the temperature set point. FLO* = Flow Switch (heater is deactivated. Pump may also be deactivated). Hold = Panel sensors have been pressed too many times in a short period of time. HOT = Circuit Board temperature has exceeded acceptable limit. ICE = Freeze protection. No action is necessary. I CE2 = Freeze protection. No action is necessary. PnL = Communication between the panel and circuit board is faulty. ---- = "Watchdog" (spa is deactivated) A problem has been detected. Sn1 = Open sensor (heater is deactivated) or Shorted sensor (spa is deactivated). Sn3 = Open or shorted sensor ( heater disabled). FLO2 = Closed or shorted flow switch on system startup BLB (or 616) = ClearRay Ozone bulb service warning. Replace bulb
Pinnacle
OH = Temperature has exceeded 110° F SN = Sensor failure FL = Flow/pressure switch stuck in closed position
Spa Builders
Sn1 = Nonfunctional high temperature sensor. Heater is deactivated. Sn2 = Nonfunctional temperature sensor. Heater is deactivated. FL1 = Water flow problem, inhibited or pressure switch malfunction. Check for proper spa water level and ensure pump is primed. Check for clogged filter. FL2 = Pressure switch problem. Switch closed while pump is deactivated. COL = Cool condition. If water temperature drops 20ºF below set temperature, low speed pump and heater activates to bring temperature within 15º of set temperature. ICE = Freeze condition. 55ºF detected. Low speed pump and heater will activate until spa reaches 65ºF. OH = High temperature condition, has reached 110ºF. Do not enter the spa. Low speed pump (and air blower if so equipped) will activate to assist in lowering temperature. --- = "Watchdog". Water temperature has reached 118ºF. Entire system is disabled. Contact qualified service technician.
Sundance Spas
ILOC = Interlock failure - possible pump or ozone spike FLO = Pressure switch malfunction or Flow switch malfunction (system specific) Hold = Panel buttons pressed to many times to quickly HOT = PCB temperature above acceptable limit - air blower on ICE = Potential freeze condition Pnl = Communication between PCB and panel interrupted Sn1 = Hi-limit sensor failure Sn3 = Temp sensor failure ---- = "Watchdog" (spa is deactivated) A problem has been detected BLB (or 616) = ClearRay Ozone bulb service warning. Replace bulb
Vita Spas
HiLi = Water temp over acceptable limit BJ2P = Pump/Blower purge - normal condition FP = Freeze protect-temp under acceptable condition SS=0; SS=S; LS=O; LS=S = Multiple causes; open sensors, bad connection to panel, improper voltage, etc.
|