Browse by Manufacturer
Spa & Hot Tub parts & accessories.
Spa Accessories
Spa Air Products
Spa Chemicals
Spa Circuit Boards
Spa Cleaning Supplies
Spa Contactors
Spa Control Panels
Spa Electrical
Spa Equipment Packs
Spa Filters
Spa Heaters
Spa Jets
Spa Lights
Spa Manuals
Spa Motors
Spa Ozone
Spa Pillows
Spa Plumbing
Spa Pumps
Spa Relays
Spa Skimmers
Spa Switches
Spa Temp Sensors
Spa Thermostats/Hi-Limits
Spa Thermowells/Drywells
Spa TimeClocks
Spa Transformers
Sundance Spas Catalog
Sundance ® Spas Accessories
Sundance ® Spas Blowers
Sundance ® Spas Circuit Boards
Sundance ® Spas Electrical
Sundance ® Spas Filters
Sundance ® Flo-Switches
Sundance ® Spas Heaters
Sundance ® Spas Jets
Sundance ® Spas Lights
Sundance ® Spas Control Panels
Sundance ® Spas Pillows
Sundance ® Spas Plumbing
Sundance ® Spas Pumps
Sundance ® Spas Ozones
Sundance ® Spas Timers
Sundance ® Part History
Spa and Hot Tub Help Pages
Sundance ® Tech Help
Sundance ® Part Catalog
Manufacturer Contact Info
Brett Aqualine
Spa Error Code
Page copy protected against web site content infringement by Copyscape
Untitled Document Spa Support Page

Need an Owner's Manual? Click on this link for all Sundance® Spas Manuals: Sundance Spa Owner Manuals 
Sundance Spas® Tech Tips:
 
Some of the most common error codes for Sundance and some tech tips to assist you with diagnoses.

1. WATCHDOG  Error Code: - - - or - - - -

The most common cause of the Watchdog error code are the sensors, specifically the temperature sensor. When the spa goes into the Watchdog the spa will not operate.
This is how it happens: When you try to use the spa, you will see 3 or 4 dashes on the control panel (depends upon the model). If you try and reset your breaker, sometimes it comes on but it will probably go back into Watchdog error - - - -. Most common cause for Watchdog is the Temperature Sensor. We have alot of people replace the high limit also and it could also be an issue.

Because this is the most common issue and one that is the least expensive to replace, We recommend you having a spare set of the Temperature and High limits in case this happens (and usually happens at the worst of times)
Here is the link for the Temperature and High Limit Sensors: http://www.spaandpoolsource.com/sundancetemperaturesensors-2.aspx

2. Temperature Incorrect or OH

Another issue that comes up and is an indication of a bad temp sensor is the temperature reading becomes inaccurate or the spa is going into the OH error code. If you power the spa down and power it back up it may work for a while but will do the same thing again. You need to replace the Temp Sensor.
See this link for the Temperature and High Limit Sensors and also a link to the Temperature and High Limit Sensor Diagnostic Guide and Harness Diagram: http://www.spaandpoolsource.com/sundancetemperaturesensors-2.aspx


3. FLO or OH Error Code

These instructions are for spas with a Flow Switch not a pressure switch. See part numbers: 6560-852, 6560-857, 6560-860 or 2560-040 for your switch type.
 If your control panel is "Flashing" FLO or OH then these are the items to consider: It is either a Dirty Filter, Defective Flow Switch or Defective Circ Pump.
1.  Dirty Filter: even when you have cleaned the filter, the filter may be impacted and be time for a new filter. The only way to test this is to make sure there is no loose debris in the spa, then pull the filter out and see if the flow error goes away, if   it does, it is the filter.
2. Defective Circ Pump or Flow Switch: Need to check for Circ Pump operation. Is there voltage going to pump, Is there adequate Flow coming out of Heater Port in Spa?
Testing to see if Circ Pump or Flow Switch. Note: This test only works on 850 Series with Circulation Pump prior to 2001: 
Try turning the #1 pump which is 2 speed. If this pump goes on on Low Speed or High Speed (if your spa has been configured for 60 amps to run the heater on high speed, note: the heater will not come on if it was not configured for 60 amps by the dealer when delivered, otherwise the heater only comes on in the Low Speed) and the Heater comes on then you Circulation Pump is defective and needs to be replaced. If the heater does not come on at all then more than likely the Flow Switch is defective and needs to be replaced.
3. Flow Switch Test:  You can test to see if the Flow Switch is defective by doing a continuity test on the flow switch by testing the 2 leads from the flow switch with the Pump off (no continuity) and Pump on (continuity). Do not bypass the Flow Switch: this could cause a potential dryfire of the heater and melt down of the heater system.
If your control panel is "Solid Flo" then the Flow Switch is defective and needs to be replaced.
Here is the link for the Flow Switches: http://www.spaandpoolsource.com/sundancespasflowandpressureswitches.aspx
Here is the link for the Circulation Pumps: http://www.spaandpoolsource.com/sundancespascirculationpumps.aspx

4. FL1 or FL 2 Error Code

FL1: Flow or pressure switch not closed when pump is running. Heater is deactivated. Proper water flow is inhibited or flow/pressure switch may be obstructed, misaligned, or defective.
Troubleshooting Steps:
1. Remove filter and allow air to bleed out of cartridge. Check filter for trapped air.
2. Check for proper water level.
3. Check for clogged filter.
4. Check secondary screen filter (Solo Models only)
5. Check for sticking or damaged weir gate.
6. Check for Flow/Pressure Switch problem.

FL2: Flow switch or pressure switch closed when pump is not running. Heater is deactivated and pump may not turn on. Flow/pressure switch is defective.

Testing Flow/Pressure Switch
These steps should only be taken after checking and testing the above steps.
Testing Flow Switch (Portofino Models Only)
   Test the Flow Switch Operation:
    With the circ pump and the main pump off, test switch operation with an ohmmeter in the continuity position, test for continuity across switch terminals. Measure resistance across switch terminals for infinite resistance. 
    With the circ pump and the main pump on, test switch operation with an ohmmeter in the continuity position, test for continuity across switch terminals. Measure resistance across switch terminals for continuity. 
    With the circ pump on and the main pump off (Portofino Models with Circulation Pump), test switch operation with an ohmmeter meter in the continuity position, test for continuity across switch terminals. Measure resistance across switch    
    terminals for continuity. If there is no continuity, turn the main pump back on, if you then have continuity, then your Circulation Pump is suspect. The Circulation Pump may be plugged up with debris or it is defective.
    If the Flow Switch test OK in all the above instances, check switch wiring harness. If wiring harness tests ok, then the Circuit Board is possibly defective.
Here is the link for Flow and Pressure Switches: http://www.spaandpoolsource.com/sundancespasflowandpressureswitches.aspx
Testing Pressure Switch (Sweetwater Models)
   Test the Pressure Switch Operation:
   Disconnect wires from Switch terminals. Set ohmmeter in the continuity position. Measure resistance across switch terminals for infinite resistance with pump off. If continuity is measured with pump off, the switch is defective. (Or debris        
   blockage, l which you have to remove switch and inspect. If debris is present, remove debris, install switch and test system. If condition still exist, replace switch.) if switch measures infinite (no continuity) with pump off, switch is OK,
   Turn on Main pump and measure across switch terminals for continuity. If continuity is measured, switch is OK. Check wiring harness, If wiring harness tests OK, then Circuit Board is possibly defective.

5. SN1 or SN 2 Error Codes

Sn1 Error Code: Heater is deactivated. High-limit sensor located in the heater drywell is nonfunctional.
Sn3: Heater is deactivated. Main temperature sensor located in filter bucket is nonfunctional.
See Temperature Sensor Diagnostic Guide: 
http://www.spaandpoolsource.com/sundancespastemperaturesensordiagnostic.aspx

6. ILOC Error Code

ILOC Error Code: Hot Tub is deactivated. Check interlock jumper located on the sensor harness. Also Turn Power off to spa at breaker and then turn system back on. 


Have a Tech Question or Request? Please email us at this link:
 http://www.spaandpoolsource.com/contact-us.aspx



 

Search
Please Input Part #
Shopping Cart
Your cart is empty.

Free Shipping On Sundance Spa Parts, Click To Read Policy !
*With a $4.95 Handling Fee Please add an item to your cart to view shipping cost. To check out please select Checkout Now. Low Price Guarntee

Hot tub spa parts, pool parts, chemicals, supplies and sundance parts
Credit Card Logo
We do not ship or sell outside of the USA!

trouble ordering ?

Click Here Please Technical Support